|
|
TM 9-4120-428-14
0005 00
Operation in Cooling Mode - Continued
8. When the temperature selector switch begins cycling the bypass circuit, make any necessary adjustment to it until the
desired shelter temperature is maintained. Allow sufficient time for the bypass circuit to cycle off and on between
adjustments.
NOTE
Cold air is denser than warm air, so it has a tendency to fall. To obtain comfortable
temperatures near the upper parts of the room, it is often advisable to adjust the
evaporator discharge louver blades to direct the air slightly upward.
9. Adjust the evaporator discharge louver blades to direct the airflow as desired.
OPERATION WITH FRESH AIR
1. Roll up and tie canvas cover if it is rolled down and secured.
2. Open the damper door by turning the ventilation damper actuator.
3. Partially close the evaporator intake louver blades.
STOPPING THE AIR CONDITIONER
1. Position the mode selector switch to OFF.
2. Close the evaporator intake louver blades by pushing tabs down.
3. Close the ventilation damper by turning the ventilation damper actuator.
4. If a shutdown is to be for an extended period, cover condenser side of unit with canvas cover and disconnect the power
cable.
DECALS AND IDENTIFICATION PLATES
A number of identification plates are provided on the exterior of the air conditioner cabinet. These plates are located on, or
adjacent to, the control or device to which they apply. Refer to the following list and illustration for each identification plate
location.
High-Pressure Charging Valve Decal
Locates charging valve.
Low-Pressure Charging Valve Decal
Locates charging valve.
Refrigeration Fluid Diagram Plate
Indicates refrigeration components.
Schematic Diagram
Indicates electrical components and wiring.
Vent Closed Decal
Indicates fresh air vent position.
Vent Open Decal
Indicates fresh air vent position.
Power Input Connector Plate
Locates input power connection.
CAUTION Grounding Decal
Grounding stud information.
Reset High Pressure Decal
Indicates location of high-pressure reset control.
Cold Weather Operation Decal
Indicates instructions for condenser louver
adjustments for cold weather operation.
Danger Plate
Warning instructions.
Reset Low Pressure Decal
Indicates location of low-pressure reset control.
Military Unit ID Plate
Indicates military model and Serial Number.
0005 00-6
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |