TM 9-4120-428-14
0033 00
Replace the Compressor circuit breaker (12) if defective.
INSTALLATION
1. Insert circuit breaker toggles through the control panel. Be sure the OFF position matches lettering on the panel.
2. Secure circuit breaker (12) to panel with screws (10) and flat washers (11).
3. Insert pin (8) and spacers (9) through circuit breaker toggles and lock them together.
4. See tags and wiring diagram (Fig. 4-4) and connect the wire leads. Remove tags.
5. Check that the grommets (14) are secure in the shaft holes.
6. Slip the back mounting plate (7) in place and align holes with three spacer posts (6). Check that the grommets (14) are
still in place in the shaft holes. Secure with three self-locking screws (5).
7. Install the knob (4) and tighten the setscrew (3).
8. Slip the control cover (2) in place and secure with four machine screws (1).
NOTE
FOLLOW-ON MAINTENANCE:
Install control module (WP 0029 00)
END OF WORK PACKAGE
0033 00-2
|