TB 9-2320-279-13-1
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM
DUCTS DURING AC OPERATIONS - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
12.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING on
Power to fan control switch OK.
Continuity test.
Blower operates.
AC condenser core not blocked or damaged.
REASON FOR QUESTION
AC compressor belts OK.
Is continuity measured
If continuity is measured, AC
AC condenser motor solenoid OK.
harness wire 1154 is
across low pressure switch?
AC condenser motor power wire OK.
faulty.
AC condenser motor ground wire OK.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
AC condenser motor OK.
AC condenser assembly harness black wire
OK.
AC harness wire 1155 OK.
Connect AC harness
AC condenser assembly harness green wire
low pressure switch
OK.
connectors and go to
NO
AC condenser motor solenoid ground wire
work package 0015
OK.
(AC Does Not Cool
Or Cools
Fan control switch OK.
Inadequately).
Wire 1156 OK.
AC temperature control switch OK.
YES
AC heater/evaporator core not blocked or
damaged.
AC temperature control switch temperature
Repair AC harness wire 1154
probe OK.
(see Appendix A). Verify
repair, go to Step 27 of this
Heater cable OK.
fault.
AC cable OK.
Defrost cable OK.
AC compressor clutch OK.
AC harness wire 1156 OK.
AC harness wire 1158 OK.
High pressure switch OK.
POSSIBLE PROBLEMS
AC harness wire 1154 faulty.
Low pressure switch faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0012-24
|