DRAFT
TB 9-2320-279-13-1
AC DOES NOT COOL OR COOLS INADEQUATELY
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Materials/Parts
Maintenance Level
Gloves, Rubber (Item 2, Appendix E)
Field Level Maintenance
Personnel Required
Equipment Condition
MOS 52C, Utilities equipment repairer (2)
Shut off engine (TM 9-2320-279-10).
Parking brake applied (TM 9-2320-279-10).
References
Wheels chocked (TM 9-2320-279-10).
TM 9-2320-279-10
Tools and Special Tools
TM 9-2320-279-20
Goggles (Item 1, Appendix F)
Tool Kit, General Mechanic's (Item 7, Appendix F)
Leak Detector, Refrigerant (Item 1, Appendix H)
Reclaimer, Refrigerant (Item 2, Appendix H)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
NOTE
AC condenser dryer must be replaced whenever system R-134a refrigerant is recovered.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
START
KNOWN INFO
Power to AC system OK.
AC heater/evaporator blower OK.
TEST OPTIONS
1.
POSSIBLE PROBLEMS
Verify preliminary tests.
Was work package 0012 (AC
AC control circuits faulty.
Heater/Evaporator Blower
REASON FOR QUESTION
AC condenser dryer desiccant contaminant in
Operates But No Cold Air
AC refrigerant system.
From Ducts During AC
is not performed before
AC refrigerant oil contaminant in AC
Operations) or work package
performing this work
refrigerant system.
package, preliminary
Restricted AC hose.
checks have not been
Not Shut Off Or Cycles
AC compressor faulty.
completed and inaccurate
Constantly) performed?
Moisture in AC refrigerant system.
results may occur.
Air or other contaminant in AC refrigerant
system.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
AC condenser core faulty.
Go to work package
AC expansion valve faulty.
NO
AC system overcharged.
Evaporator Blower
Operates But No
AC condenser dryer faulty.
Cold Air From Ducts
AC evaporator core faulty.
During AC
YES
AC system charge low.
Operations).
AC system leaking.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
(0015-1 blank)/0015-2
|