TB 9-2320-279-13-1
AC DOES NOT COOL OR COOLS INADEQUATELY - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
4.
KNOWN INFO
TEST OPTIONS
Read WARNING on
Power to AC system OK.
Visual inspection.
AC heater/evaporator blower OK.
REASON FOR QUESTION
AC control circuits OK (except for
temperature control and low pressure
Does AC condenser dryer
If system is not fully charged,
switches).
system may not cool
sight glass indicate system is
AC low pressure switch OK.
properly.
fully charged?
No AC condenser dryer desiccant
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
contaminant in AC refrigerant system.
No AC refrigerant oil contaminant in AC
refrigerant system.
POSSIBLE PROBLEMS
Perform leak test
Restricted AC hose.
(WP 0049). If leaks
AC compressor faulty.
NO
are found, recover
Temperature control switch faulty.
R-134a refrigerant
Moisture in AC refrigerant system.
(WP 0050), repair
leaks, and replace
Air or other contaminant in AC refrigerant
YES
AC dryer (WP 0025).
system.
Charge system to full
AC condenser core faulty.
charge (WP 0050)
AC expansion valve faulty.
and go to Step 5 of
AC system overcharged.
this fault.
AC condenser dryer faulty.
AC evaporator core faulty.
AC system charge low.
AC system leaking.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0015-8
|