DRAFT
TB 9-2320-279-13-1
AC SYSTEM REFRIGERANT (R-134a) MAINTENANCE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
THIS WORK PACKAGE (WP) COVERS:
Recovery
Evacuation
Charging
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Materials/Parts
Maintenance Level
Gloves, Rubber (Item 2, Appendix E)
Field Level Maintenance
Oil, PAG 46 (Item 3, Appendix E)
Equipment Condition
Refrigerant, R-134a (Item 4, Appendix E)
Engine cover opened and engine side panel
Personnel Required
removed (TM 9-2320-279-10).
MOS 52C, Utilities equipment repairer
Tools and Special Tools
References
Goggles (Item 1, Appendix F)
TM 9-2320-279-10
Set, Cap and Plug (Item 3, Appendix F)
Tool Kit, General Mechanic's (Item 7, Appendix F)
Leak Detector, Refrigerant (Item 1, Appendix H)
Reclaimer, Refrigerant (Item 2, Appendix H)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |