TB 9-2320-279-13-1
AC ALTERNATOR AND PULLEY REPLACEMENT
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
THIS WORK PACKAGE (WP) COVERS:
Removal
Installation
Follow-On Maintenance
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Materials/Parts
Maintenance Level
Sealant, RTV200 Electrical (Item 6, Appendix E)
Field Level Maintenance
Tags, Identification (Item 9, Appendix E)
Equipment Condition
Personnel Required
Batteries disconnected (TM 9-2320-279-20).
MOS 52C, Utilities equipment repairer (2)
Left splash guard removed (TM 9-2320-279-20).
AC alternator drive belts removed (WP 0019).
References
Tools and Special Tools
TM 9-2320-279-20
Shop Equipment, Common No. 1 (Item 4,
Shop Equipment, Common No. 2 (Item 5,
Tool Kit, General Mechanic's (Item 7, Appendix F)
REMOVAL
HEMAC001
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1. Remove nut (1), lockwasher (2), and two wires (3 and 4) from terminal (5).
2. Remove nut (6), lockwasher (7), and wire (8) from terminal (9).
3. Remove nut (10), lockwasher (11), and two wires (12 and 13) from terminal (14).