TB 9-2320-279-13-1
AC HEATER/EVAPORATOR BLOWER MOTOR RESISTOR REPLACEMENT -
Continued
REMOVAL
HEMAC058
1. Remove four screws (1), lockwashers (2), washers (3), and cover (4) from heater/evaporator (5).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
HEMAC059
NOTE
Tag and mark connectors prior to removal to ensure proper installation.
2. Disconnect connector (6) from resistor (7).
3. Remove two screws (8) and resistor (7) from bracket (9).