DRAFT
TB 9-2320-279-13-1
AC HEATER/EVAPORATOR BLOWER MOTOR RESISTOR REPLACEMENT -
Continued
INSTALLATION
HEMAC059
1. Install resistor (7) on bracket (9) with two screws (8).
2. Connect connector (6) to resistor (7).
HEMAC058
3. Install cover (4) on heater/evaporator (5) with four washers (3), lockwashers (2), and screws (1).
FOLLOW-ON MAINTENANCE
1. Install AC upper plenums (WP 0045).
2. Connect batteries (TM 9-2320-279-20).
END OF WORK PACKAGE
0035-3/(0035-4 blank)
|