TB 9-2320-279-13-1
AC UPPER PLENUM REPLACEMENT
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
THIS WORK PACKAGE (WP) COVERS:
Removal
Installation
Follow-On Maintenance
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Materials/Parts
Maintenance Level
None
Field Level Maintenance
Personnel Required
Equipment Condition
MOS 52C, Utilities equipment repairer
AC heater/evaporator cover removed (WP 0037).
References
Tools and Special Tools
TM 9-2320-279-20
Tool Kit, General Mechanic's (Item 7, Appendix F)
REMOVAL
HEMAC061
NOTE
Perform Step 1 if gasket needs to be replaced.
1. Remove gasket (1) from two upper plenums (2).
2. Remove six screws (3) from two upper plenums (2) and lower plenum (4).
3. Remove two screws (5), lockwashers (6), washers (7), and two upper plenums (2) from cover (8).