DRAFT
TB 9-2320-279-13-1
AC HEATER/EVAPORATOR REPLACEMENT - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
HEMAC029
18. Secure two drain hoses (15) together with cable tie (14).
HEMAC028
19. Install preformed packing (12) and hose (11) on fitting (13). Torque hose (11) to 11-13 ft-lbs.
(15-18 Nm).
20. Install preformed packing (9) and hose (8) on fitting (10). Torque hose (8) to 18-22 ft-lbs. (24-30 Nm).
21. Install two heater hoses (6) on flanges (7) and tighten clamps (5).
0038-13
|