TB 9-2320-279-13-1
CAUTION
Strip wire after placing it through seal.
Failure to comply may cause damage to
equipment.
3.
Insert 1 in. (25 mm) of wire (6) through
seal (8).
4.
Strip end of wire (6), leaving 1/4 in. (6 mm)
of bare wire.
5.
Insert contact socket (9) in locating hole of
crimper using proper hole according to the
gage of wire (6).
6.
Slide seal (8) down to end of insulation on wire (6).
7.
Position wire (6) on contact socket (9).
8.
Press handles of crimper together until ratchet releases and crimping is complete.
9.
Repeat Steps 3 through 8 for wire (7).
10. Push contact socket (9), seal (8), and wire (6) through position A on connector (10).
11. Push contact socket (9), seal (8), and wire (7) through position B on connector (10).
12. Close secondary lock (11) on connector (10).
0052-18
|