DRAFT
TB 9-2320-364-13&P-1
AC CONDENSER MOUNTING BRACKET REPLACEMENT - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PLSAC003
3. Loosen locknut (4).
WARNING
AC condenser assembly weighs 75 lbs. (34 kg). Do not lift AC condenser assembly
without the aid of an assistant. Failure to comply may result in injury to personnel
and/or damage to equipment.
NOTE
After being removed from condenser mounting bracket, condenser will be positioned on
top of two wooden blocks that were installed in Step 2.
bracket (7).
5. Remove locknut (8), screw (9), and support bar (10) from condenser mounting bracket (7).
Discard locknut.
6. Remove two screws (11) and washers (12) from condenser mounting bracket (7) and panel (13).
0027-3
|