DRAFT
TB 9-2320-364-13&P-1
AC HEATER/EVAPORATOR BLOWER MOTOR ASSEMBLY REPLACEMENT
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
THIS WORK PACKAGE (WP) COVERS:
Removal
Installation
Follow-On Maintenance
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Maintenance Level
Materials/Parts
Field Level Maintenance
Tags, Identification (Item 10, Appendix E)
Tape, Insulation, Electrical (Item 11, Appendix E)
Equipment Condition
Lockwashers (7) (Item 4, Figure 5, Appendix G)
Batteries disconnected (TM 9-2320-364-20).
Personnel Required
Heater/defroster tubing (upper plenums) removed
(TM 9-2320-364-20).
One
Tools and Special Tools
References
Tool Kit, General Mechanic's (Item 9, Appendix F)
TM 9-2320-364-20
REMOVAL
PLSAC065
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1. Remove screw (1), lockwasher (2), washer (3), and ground wire (4) from heater/evaporator (5). Discard
lockwasher.
2. Remove three screws (6), lockwashers (7), washers (8), and cover (9) from heater/evaporator (5).
Discard lockwashers.