DRAFT
TB 9-2320-364-13&P-1
AC HEATER/EVAPORATOR REPLACEMENT - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PLSAC140
18. Install two heater hoses (11) on flanges (13) and tighten clamps (12).
19. Close front access cover (10).
PLSAC138
NOTE
Lightly lubricate preformed packings with PAG oil prior to installation.
Ensure preformed packings are in place in hoses prior to installation.
20. Install preformed packing (7) and hose 2524 (6) on fitting (8). Torque hose (6) to 11-13 ft-lbs.
(15-18 Nm).
21. Install preformed packing (4) and hose 2522 (3) on fitting (5). Torque hose (3) to 18-22 ft-lbs.
(24-30 Nm).