6. If the wire is too short to make a secure connection, use the existing wire to pull a replacement wire
through the conduit from the junction box at the light fixture.
7. Inspect the light switch. If the switch is damaged, go to Step 9.
8. Turn the switch on. Using the multimeter, check continuity between the switch input and output
terminals. If you do not detect continuity, go to Step 9. If there is continuity, change the wires as
described in Step 3.
9. Remove the damaged switch assembly. Loosen the wire terminal screws on the switch, tag and
disconnect the wires from the terminals.
10. Connect the wire ends to the replacement switch, ensuring that each tagged wire is connected to the
proper terminal. Make sure the terminal screws are secure.
11. Insert the new switch in the enclosure, making sure no wires are pinched. Install the retaining screws
removed in Step 3.
12. Replace the cover plate and screws removed in Step 2. Make sure the gasket is in good condition
and properly located.
13. If no gasket is available or if it is not serviceable, caulk the perimeter of the plate with silicone sealant
to provide a watertight seal.
14. Connect a 110 VAC 60 Hz power supply to the power input connector and test the operation of the IC
electrical system as described in Work Package 0018 00.
0021 00-2
|