ADVANCED DESIGN REFRIGERATOR, 300 CUBIC FOOT (ADR-300)
IC INTERIOR LIGHT SWITCH AND PILOT LIGHT
REPAIR
INITIAL SETUP
Personnel Required
Tools and special tools
Electrical Technician MOS 51 (AFSC 3E0X1)
Tool Kit, Organizational Maintenance
HVAC Technician MOS 52C (AFSC 3E1x1)
(WP 0051 00, Table 2, Item 4)
Multimeter (WP 0051 00, Table 2, Item 2)
References
Materials and Parts
Interior Light Switch (WP 0056 00, Item 5)
Equipment Conditions
ADR-300 set up (See WP 0005 00 for set-up
Pilot Light (WP 0056 00, Item 3)
procedures).
Sealant (WP 0068 00, Item 21)
GENERAL
This work package outlines steps for repairing and replacing the interior light switch and/or the pilot light
in the insulated container. Before beginning this procedure, complete the IC electrical system test
outlined in Work Package 0018 00. The light switch or pilot light should be replaced only by an identical
part or an approved substitute.
REPAIR
Light Switch
WARNING
The IC electrical system has high voltage components
that, if contacted, may cause serious injury or death.
Failure to comply may result in serious injury or death of
personnel.
1. Confirm that the IC power supply cord is disconnected from the IC power entry connector.
2. Remove the four screws that hold the cover plate for the light switch. Remove the cover plate and
gasket (if present). Set the cover plate, gasket and screws aside.
3. Remove two screws that retain the light switch in the enclosure. Pull the switch out of the enclosure
to the limit of the attached wires.
4. Look for loose, broken or burned wires. Reconnect loose wires to the appropriate screw terminals as
shown.
5. For broken or burned wires, strip about in. of insulation from the wire on the container-side of the
break and connect the wire to the switch terminals.