TM 10-4110-262-13&P
OPERATOR'S, UNIT, AND DIRECT SUPPORT MAINTENANCE
ADVANCED DESIGN REFRIGERATOR, 300 CUBIC FOOT (ADR-300)
OPERATION UNDER USUAL CONDITIONS
SITING REQUIREMENTS
WARNING
The ADR-300 weighs as much as 10,000 lb (4,536 kg) when fully loaded.
Lift and move the container only with material handling equipment of at
least 10,000-pound (4,536 kg) capacity. Observe all safety precautions.
Never stand under an ADR-300 when it is being lifted.
This section outlines the site requirements for the ADR-300. It also provides procedures for the
preparation and operation of the ADR-300 under usual conditions. See Work Package 0006 00,
Operation Under Unusual Conditions.
The selected site should be relatively level and free of rocks and other obstructions. It should provide for
adequate drainage of ground water. The cleared area should be large enough for the container itself and
permit unrestricted movement of cargo handling equipment.
The site should have adequate electric power available. The ADR-300 requires 208/230 VAC, 3-phase,
50-60 Hz power up to 30 A (see WP 0002 00). No other facilities are required for normal operation.
NOTE
The compressor overload should be set at different levels, depending on
the supply power frequency. The unit is set at the factory at 15 A for 60
Hz power. When used with 50 Hz power, the overload relay should be
set to 12.5 A. See Work Package 0029 00 for checking and adjusting
the overload relay setting.
ASSEMBLY AND PREPARATION FOR USE
Unloading and moving the ADR-300 requires a forklift or an overhead crane with a lifting capacity of at
least 10,000 pounds (4,536 kg). When using a forklift, use the built-in forklift pockets on the container
base.