Fractures Less Than 1 X 3-in. (3.8 X 7.6 cm) Aluminum Bonded Material
The following procedure should be used to repair skin fractures with an area of less than 1 x 3 in. (3.8 x
7.6 cm):
1. Brush the damaged area with a stiff wire brush to rid it of foreign material, grease, and dirt.
NOTE
If the punctured or gouged area in the panel is surrounded by extended
cracks, drill the ends of all cracks using 1/8-in. drill (see figure) to stop
the crack from growing.
2. Drill a hole at the ends of all tears or cracks ("stop-drill") in the face skin with a 1/8-in. drill bit.
WARNING
Isopropyl alcohol is toxic and flammable. Do not consume
internally and avoid inhaling vapors. Good, general
ventilation is normally adequate. Avoid all sources of
ignition. Failure to comply may result in serious injury or
death to personnel.
NOTE
Fill damaged areas no larger than 1-1/2 x 3 in wide and no closer than
two feet apart. Larger area damage should be referred to an intermediate
maintenance area for repair.
Stop Drill
Points
Typical Minor Damage to Single Surface
Repair of Minor Damage to Single Surface