ADVANCED DESIGN REFRIGERATOR, 300 CUBIC FOOT (ADR-300)
CONDENSATE DRAIN HEATER
REMOVE/INSTALL
INITIAL SETUP
References
Tools and special tools
None
Tool Kit, Organizational Maintenance
(WP 0051 00, Table 2, Item 4)
Equipment Conditions
ADR-300 disconnected from all sources of
Materials and Parts
power.
Harness Heater, Drain Tube
Personnel Required
(1)
REMOVE
WARNING
The components on the evaporator have sharp edges and will cut hands
and other exposed skin surfaces. Take care to avoid contact with the
components. Failure to comply may result in serious injury to personnel.
1. From inside the IC, trace the drain tube heater wires from the drain tubes to their respective electrical
connectors. Disconnect the heater wires.
2. Remove the heater wires from the condensate drain tubes through the "Y" fitting at the rear of the
condensate drain pan.
INSTALL
1. Insert the looped end of one drain heater wire into each of the two condensate drain hoses.
2. Insert the wire into the "Y" fitting at the rear of the condensate drain pan.
3. Slide the wire into the tube until only enough wire is exposed to reach from the drain pan connection
to the electrical connectors for the heater wires.
4. Insert the opposite end of the wire into the hose and past the tee to the drain at the back of the unit.
Repeat for the other side.
5. Connect the heater wires to their respective electrical connectors.