TM 10-4130-239-14
4-29. STARTER PANEL ASSEMBLY REPLACEMENT (CONT)
To prevent electric shock, make sure power is disconnected from 12
VOLT INPUT FOR STARTING connection before performing this
procedure.
7. Place red lead on starter terminal. Press starter button S7. If voltage is present, cable is good.
If voltage is less than voltage at starter button, replace cable.
1. Disconnect power cable from 12 VOLT INPUT FOR STARTING connection.
2. Remove mounting nut, lockwasher, and flatwasher. Remove toggle switch S3 from mounting
bracket.
4-56