TM  10-4130-239-14 4-31. ARMATURE  GROUP  REPLACEMENT  (CONT) 3. 4. 5. 6. 7. 8. 9. Move  starter  panel  assembly  aside. Insert 0.010 in. (O. 254 mm) thickness gauge between armature and flywheel with magnet directly in front of armature. Loosen  two  armature  mounting  bolts. Allow magnet to pull armature  down  firmly  against  thickness  gauge. Tighten  two  armature  mounting  bolts. Remove  thickness  gauge. Install blower housing. Install  eight  blower  housing  mounting bolts and starter clamp. Install. flywheel pulley. Install  two  flywheel  pulley  mounting bolts and two lockwashers. 4-66