PMCS CONTINUED
Table 1. Maintainer Maintenance Preventative Maintenance Checks and Services (PMCS) Continued.
Item
Interval
Item To Be
Procedure
Equipment
No.
Checked or
Not Ready/
Serviced
Available If
2
After
g. Check condition and level of compressor oil.
Refrigeration
Initial
Unit
400
Hours
(continued from
NOTE
previous page)
The refrigeration unit must operate in high speed
for twenty (20) minutes before checking
compressor oil level.
1. Check oil sight glass (8) on compressor (9) to make
Foaming is
sure no foaming of oil is present.
present in sight
glass.
2. Check that compressor (9) oil level is 1/2 present in
Oil level not
oil sight glass (8).
within
tolerance.
0011-5