6.  Allow the battery to stand for 30 minutes after filling. Then check electrolyte specific gravity of each cell
correcting the readings to 1.280 at 800F (26.7C). Add electrolyte if necessary to bring the electrolyte up to the designated
level.
7.  The battery should be charged fully before it is put into service. If time or equipment is not available it
may be used unless one of the following conditions exist:
The specific gravity of the electrolyte, corrected to 80F (26.70C), of any cell is below 1.250 after the 30
minute stand. The battery is going into service at temperatures below 0F (-17.80C).
8.  If either of the two conditions exist, the battery should be charged constant current at the 20-hour rate
until specific gravity becomes constant for three consecutive 30-minute readings. Constant potential may be used if
battery electrolyte temperature is maintained below 1300F (54.70C) by interrupted charging or by lowering the charging
voltage, and the final charging current is equal to the 20 hour rate. If the specific gravity of battery, temperature corrected,
exceeds 1.290 it should be adjusted to 1.280 0.010. After a short period of service (10 to 14 days) the specific gravity
should be checked and if the battery is less than a 3/4 charged, it should be charged as indicated in the above instructions.
9.
Check the electrolyte levels frequently. Add distilled or drinking water as required to maintain the proper
level.
10. Keep the top and sides of the battery clean and dry. Make sure the vent filler plugs are clean. When
cleaning is required wash with water.
11. Battery should be charged once a month and kept in cool, dry storage when not in use.
12. Before disposing of empty electrolyte container, neutralize excess acid with baking soda and rinse
container with water.
13. Legibly stamp or brand the date (month and year) on the battery container adjacent to the negative post.
The date should be preceded by the letter "S" (example: S-5-80).
If the battery was removed from the unit it should now be reinstalled. (See fig. 4-4)
Be sure the REFRIGERATOR ON-OFF toggle switch is in the off position.
Connect the positive battery cable to the positive terminal adapter. Be sure this is done prior to connecting the
negative cable.
Connect the negative battery cable to the negative terminal adapter.
(2)  Power cable connection for F10000R-6 only.
The power cable is not supplied with the unit.
Use type S or SO heavy duty portable cord with four conductors of AWG number 10 wires and of an overall
jacket diameter not exceeding 0.745 inch (1.9 cm).
Determine the length and type of connections required to connect to the power source.
The power source must be 208 volt, three phase, 60 hertz, 4 wire ac electric power.
The connection at the power source must be equipped with a positive shut off or disconnect so that power
can be shut off for safe maintenance of the refrigerator.
See wiring diagram figure 4-5 for correct phase and ground relationship.