Page Title: Figure 5-11. Valve Plate Removed
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM5-4110-234-14
TO 40R7-5-7-1
Figure 5-11. Valve Plate Removed
(4)
Remove suction valves and suction valve positioning springs from dowel pins. See figure 5-12.
Figure 5-12. Suction Valve and Positioning Springs in Place
(5)  Inspect the valves, valve seats, and valve springs for wear or damage. Replace complete valve plate if
cracked or worn.
WARNING
Dry cleaning solvent (Fed Spec P-D-680) used to clean parts is potentially dangerous to
personnel and property. Do not use open flame or excessive heat. Flash point of solvent
is 100F to 138F (38C to 59C).
5-34