TM 5-4110-240-13&P
REMOVE/TEST/INSTALL VAPOR PROOF LIGHT AND GLOBE
TOOLS: Screwdriver, flat-blade
REMOVAL:
WARNING
Disconnect power to power receptacle before beginning this procedure.
1. Remove screws (1) and gently pull vapor proof light socket (2) away from wall.
2. Tag and disconnect wires (3) to vapor proof light.
TEST:
1. Attach a 1 25 V ac power source to vapor proof socket.
2. Use a Multimeter to check voltage across socket.
INSTALLATION:
1. Connect wires (3) to vapor proof light and remove wire tags.
2. Mount socket (2) onto wall using screws (1).
3. Reconnect power to power receptacle.
Change 2 4-28
|