equipped with fan motor run capacitors which are
(2) Refer to figure
4-16 and disconnect
located in the evaporator air inlet compartment.
capacitor leads.
b. Rernoual. Remove fan motor capacitors as
(3) Remove screw and bracket l nd slide
follows :
capacitors outward from air conditioner.
(1) Refer to paragraph 4-18 and remove the
evaporator air inlet louver.
Figure 4-16. Fan motor capacitors.
c. Installation. Install capacitors as follows:
(2) Connect capacitor leads.
(1) Refer to figure 4-16 and install capacitors,
( 3 ) R e f e r t o p a r a g r a p h 4 - 1 8 a n d i n s t a ll
bracket, and screw.
evaporator air inlet louvers.
Section XIV. MAINTENANCE OF CONTROL MODULE
4-43. General
breaker, temperature selector switch, mode selector
The control module is located in a compartment in
rotary switch, and the evaporator fan speed toggle
the junction box. All electrical connections to the
switch.
control module are through plug-in type connectors
Warning: Disconnect air conditioner power
permitting easy removal of the module as a unit.
supply before removing control module.
The control module contains the compressor circuit
4-25
|