across  terminals  of  switch.  If  no  continuity  is  in- (4) If switch is not defective, connect leads and dicated,  press  reset  button  and  recheck. install  junction  box. (3)  If  switch  is  defective,  report  condition  to direct  support  maintenance. Section  XVII.   COMPRESSOR 4-59.  General Organizational  maintenance  of  the  compressor  is limited  to  the  inspection,  testing  and  repair  of  the electrical  equipment. 4-60.  Inspection,  Testing  and  Repair. a.  Refer  to  paragraph  4-21  and  remove  housing rear  top  cover. b.  Refer  to  figure  4-22  and  disconnect  electrical connector. c.  Follow  procedure  outlined  in  paragraph  4-37 and  test  motor. d.  If  any  deficiency  is  indicated,  remove  screws and  terminal  box  cover  and  check  for  damaged wiring  or  loose  connections.  Repair  damaged wiring  and  tighten  loose  connections.  If  this  does not   correct   the   trouble,   report   the   condition   to direct  support  maintenance. e. Install terminal box cover and screws. Connect electrical  connector.  Refer  to  paragraph  4-21  and install  housing  rear  top  cover. 4-61.  Compressor  Capacitors  and  Relay a.  General.  Single   phase   air   conditioners   are equipped  with  a  compressor  start  capacitor  and relay  and  a  compressor  run  capacitor.  The  com- pressor  run  capacitor  is  located  in  the  evaporator air  inlet  compartment  over  the  evaporator  fan motor.  The  compressor  start  capacitor  and  relay are located under the counter top cover on the inner wall  of  the  junction  box  compartment  of  the housing. b.  Removal.  Remove  the  compressor  capacitors and  relay  as  follows: (1) Remove housing covers (para 4-21) to gain access   to   start   capacitor   and   relay.   Remove evaporator  air  inlet  louver  (para  4-18)  to  gain access  to  compressor  run  capacitor. (2) To remove start capacitor, refer to figure 4- 23,  disconnect  leads  and  remove  capacitor  from retainer. Figure 4-22.  Compressor electrical connector and terminal box cover. 4-35

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business