4120-01-091-9672">
|
|
TM 5-4120-339-14
e. Evaporator Discharge Grille.
(1) Removal. (See figure 3-3.)
(2) Cleaning.
(a) Wash grille with a stream of fresh water.
WARNING
When using compressed air for blowing and cleaning, air hose pressure must not
exceed 30 psig (2ks/cm2), and individuals must wear eye protection equipment.
(b) Dry grille with compressed air.
(3) Inspection.
(a) Inspect grille for bent, dented or broken parts.
(b) Inspect grille for missing, damaged or loose gasket.
(c) Inspect grille for missing or defective attaching hardware.
(4) Repair.
(a) Straighten minor bends and dents in grille.
(b) Replace defective or missing gasket. New gaskets are installed by removing the strip from the gasket
adhesive backing and pressing the gasket into place on the grille.
(c) Replace missing or defective attaching hardware.
(5) Replace. Replace grille if damaged beyond repair.
(6) Installation. (See figure 3-3.)
f.
Fresh Air Inlet Screen.
(1) Removal. (See figure 3-3.)
(2) Cleaning.
(a) Wash screen with a stream of fresh water.
WARNING
When using compressed air for blowing and cleaning, air hose pressure must not
exceed 30 psig (2ks/cm2), and individuals must wear eye protection equipment.
3-12
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |