GENERAL SUPPORT MAINTENANCE INSTRUCTIONS
Section/Paragraph
Repair Parts Special Tools, TMDE, and Support
Authorized General Support Maintenance Actions II
Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...I
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6-2
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..6-1
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6-3
Section I.
R E P A I R PARTS, SPECIAL TOOLS, TMDE, A N D S U P P O R T E Q U I P M E N T
GENERAL
Repair parts are listed and illustrated in TM 5-4120-347-24P. No special tools are required for general support
maintenance of the air conditioner. Test, maintenance, and diagnostic equipment (TMDE), and support
equipment, includes standard electrical test equipment, and standard pressure and vacuum gages, vacuum
pumps, and servicing manifolds found in any general support maintenance refrigeration facility.
Section II
AUTHORIZED GENERAL SUPPORT MAINTENANCE ACTIONS
GENERAL
The only items restricted to general support maintenance level by the Maintenance Allocation Chart (MAC)
are the repair or replacement of insulation or lifting fittings on the casing, and replacement of the cabinet base.
However, general support maintenance may be called upon, at times, to perform any or all of the MAC items
listed for organizational and direct support maintenance for rehabilitation or overhaul of an air conditioner.
HOUSING
See paragraph 4-47 for inspection and service of the housing.
a. Repair.
(1) Repairs are limited to rework of broken or cracked welds, straightening of bent or dented sheet metal
and replacement of handles, gaskets, insulation and rivnuts and some small sheet metal parts by drilling out
rivets and installation of replacement parts.
(2) Disassemble unit as necessary and make repair as indicated.
(3) Gasket and insulation replacement.
(a) Use only gaskets, insulation or name plates identified in TM5-4120-347-24P.