TM 5-4120-356-14
CONTINUITY CHECKING
1.
TURN SHAFT OF SELECTOR SWITCH COUNTER-CLOCKWISE UNTIL IT STOPS (POSITION 1).
2.
REFER TO WIRING CHART AND CHECK FOR CONTINUITY BETWEEN TERMINALS SHOWN FOR
WAFERS A, B, C AND D, POSITION 1.
3.
TURN SHAFT OF SELECTOR SWITCH CLOCKWISE ONE CLICK TO POSITION NO. 2. CHECK FOR
CONTINUITY BETWEEN TERMINALS SHOWN FOR WAFERS A, B AND C, POSITION 2.
4. TURN SHAFT OF SELECTOR SWITCH CLOCKWISE TWO CLICKS TO POSITION NO 4. CHECK FOR
CONTINUITY BETWEEN TERMINALS SHOWN FOR WAFERS B AND C, POSITION 4.
5. TURN SHAFT OF SELECTOR SWITCH CLOCKWISE ONE CLICK TO POSITION NO. 5. CHECK FOR
CONTINUITY BETWEEN TERMINALS SHOWN FOR WAFERS A, B, C AND D, POSITION NO. 5.
TS5-4120-356-14/3-10
Figure 3-10. T e s t p r o c e d u r e s f o r s e l e c t o r s w i t c h
|