b. Removal - Model DHF
(1) Discharge the refrigerant system per paragraph 4-5.
(2) Using screwdriver and wrench, remove two screws and lock nuts that hold push-pull control cables.
(3) Using wrench, loosen and disconnect flare nut.
(4) Using wrench, remove two lock nuts that secure cylinder to bracket.
(5) Remove actuating cylinder.
Figure 4-79.1. Actuating Cylinder - Models EKP and FGG
c.
Removal - Models EKP and FGG
(1) Discharge the refrigerant system per paragraph 4-5.
(2) Using screwdriver and wrench, remove two screws and lock nuts that hold push-pull control cables.
(3) Using wrench, loosen and disconnect flare nut.
(4) Using wrench and screwdriver remove two lock nuts and screw that secure cylinder to bracket.
(5) Remove actuating cylinder.
4-158 Change 5
|