TM5-4120-376-14 4-23.  AMBIENT  THERMOSTAT  AUXILIARY  POWER  INLET/Inspect,  Test,  Repair,  Replace (Cont) LOCATION/ITEM Removal: 8.  Tag  and  remove  wires  from terminal  board  (22)  and  ground screw   (23). 9.   Remove   inlet   connector   assy (J-1). Inspection: 1.   Inspect   for   damage. 2.  Repair  or  replace  if  damaged. Repair: 1.   To   repair   broken   or   cut   wires and  spliced. 2.   A   commercial   butt   splice   can be  made. that  are  otherwise  sound,  the  mating  ends  can  be  stripped be  crimped  onto  the  ends  to  join  them,  or  a  wire  splice  can 3.  A  wire  splice  is  made  by  stripping  one  1  1/4  inches  of  insulation  from  the  wire  ends, holding   the   ends   parallel   and   facing   opposite   directions,   then   twisting   each   end   around   the   other wire  at  least  three  turns. 4.   Solder   and   apply   heat-shrink   tubing. 4-129