TM5-4120-376-14
4-23. AMBIENT THERMOSTAT AUXILIARY POWER INLET/Inspect, Test, Repair, Replace
(Cont)
LOCATION/ITEM
Inspection:
1. Inspect for damage.
2. Repair or replace if damaged.
1. Remove damaged section of wire.
2. Strip insulation 1-1/4 inches off both ends of damaged wire.
3. Insert new section of wire, stripped 1-1/4 inches on both ends.
4. Twist wires together on both ends.
5. Solder and insulate.
Installation:
1. Align auxiliary inlet power connector assembly (J-12) (13) with gasket (18) dust cover (17)
and holes in housing.
2. Secure above with four screws (14) four flat washers (15) and four lock nuts (16).
3. Secure auxiliary inlet power connector assembly (J-12) to housing with two clamps (10)
two screws (11) and two lock washers (12).
4. Attach connector (J-12) (19) to bulkhead.
4-134
R e p a i r:
|