TM5-4120-376-14
4-24. HEATER, TRANSFORMER, RECTIFIER AND RELATED PARTS/Inspect, Test, Replace
(Cont)
LOCATION/ITEM
Test:
5. Replace defective capacitor.
Installation:
Capacitors (C-1) and (C-2)
1. Slip heat shrink tubing over capacitor wires.
2. Solder capacitor wires to appropriate terminals on rectifier.
Transformer
1. Solder wires to appropriate terminals on transformer (18) in accordance with Appendix E
and remove tags.
2. Attach wires to appropriate
terminals on terminal board (19)
in accordance with Appendix E and
remove tags.
3. Align transformer (20) with
housing.
4. Secure transformer to housing
with four screws (15), four lock
washers (16) and four flat washers
(17).
Rectifier
1. Solder wires to transformer (18)
in accordance with Appendix E and
remove tags.
2. Attach wires to terminal
board (19) at appropriate terminals.
3. Align rectifier (21) with
housing.
4. Secure rectifier to housing
with two screws (20).
5. Install junction box in
accordance with paragraph 4-22,
page 4-118.
4-149
|