TM5-4120-376-14 5-19.  REFRIGERANT  VALVES  AND  RELATED  TUBING/Test,  Repair,  Replace  (Cont) LOCATION/ITEM EXPANSION   VALVE/QUENCH   VALVE/SOLENOID   VALVE/PRESSURE   REGULATING   VALVE Installation: WARNING 1. with 2. 3. Avoid   contact   with   refrigerant   acid.   Burns   could   result   from   contact   with refrigerant. Refrigerant  R-22  is  contained  in Extreme   care   must   be   exercised WARNING the  refrigerant  system  under  high  pressure. to   prevent   refrigerant   from   coming   in   contact with  exposed  skin  and  eyes.    Provide  adequate  ventilation  when  discharging  the system  in  a  confined  area.    All  refrigerant  gas  must  be  discharged  from  system before   performing   any   removal   procedures   of   refrigerant   components. CAUTION Maintain  a  1-2  cpm  (0.1-0.2  M 3/Min)  flow  of  dry  nitrogen  through  the refrigeration  system  to  prevent  oxidation  and  scaling  when  brazing  or  debrazing components. NOTE Wrap   valve   with   wet   cloth   to   prevent   overheating   valve   during   soldering. Align  sensor  bulb  (18)  and  one  clamp  (17)  with  sensor  bulb  mounting  bracket  and  secure one  screw  (15)  and  one  lock  washer  (16). Braze  in  accordance  with  paragraph  5-10,  page  5-12. Install  one  clamp  (12)  around  pressure  regulating  valve  (14)  and  align  with  spacer  post  (13) on  hole  in  bulkhead  and  secure  one  screw  (11). 4.  Secure  sensor  bulb  (18)  to  suction  line  (19)  with  cable  strap  (10). 5.  Test,  evacuate  and  charge  system  in  accordance  with  paragraphs  5-8  through  5-14,  pages 5-10  through  5-19. SOLENOID   VALVE   (L-1)   (L-2) 6. 7. 5-40 Braze  in  accordance  with  paragraph  5-10,  page  5-12. Secure   solenoid   valve   base   (20)   to   bulkhead   with   two   screws   (19).

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business