TM5-4120-376-14
5-19. REFRIGERANT VALVES AND RELATED TUBING/Test, Repair, Replace (Cont)
L O C A T I O N / I T E M
Installation:
8. Install O-ring (17) in groove in plunger assembly (14) and place diaphragm (18) in recess of
base (16) with the seat facing upwards.
9. Secure plunger assembly (14) to valve base (16) with two screws (15).
10. Install coil (13) nameplate (12) and retaining nut (11) to plunger assembly and tighten nut
(11).
11. Connect electrical
connector P-8 (10).
12. Test, evacuate and
charge system in accordance
with paragraphs 5-8 through
5-14, pages 5-10 through 5-19.
5-41
|