TM5-4120-376-14
4-14. CONDENSER GUARD, COVERS, VENTILATION AIR FILTER AND LIFTING
RINGS/Inspect, Service, Repair, Replace (Cont)
LOCATION/ITEM
Service:
WARNING
Dry cleaning solvent, P-D-680 or P-S-661, used to clean parts is potentially
dangerous to personnel and property. Avoid repeated and prolonged skin
contact. Do not use near open
is 100°F (38°C).
1. Immerse the ventilation air filter
3) and stir until dirt is removed using a
flame or excessive heat. Flash point of solvent
in soap solution or dry cleaning solvent (Table D-1, Item
soft brush if necessary to loosen caked-on dirt.
2. Rinse in clean water or dry cleaning solvent.
3. Hold ventilation air filter horizontal and tap each edge on bench or floor to ensure all
water is removed.
Installation:
1. Install ventilation air filter (4) in ventilation guard (3).
2. Align ventilation guard (3) with holes in housing and secure ventilation guard with four
screws (1) and four lock washers (2) to housing.
4-36
|