REFRIGERATION SYSTEM REPAIRS GENERAL.
The refrigeration system must be totally discharged before any
maintenance action is performed on any system component.
Leak
testing and dehydrator replacement is required after any system
component has been removed and replaced.
The system must be
evacuated before it is charged.
The system must be properly
charged to function properly.
DANGEROUS CHEMICAL
is
used in this equipment.
DEATH
or
severe injury may result if personnel
fail to observe safety precautions.
Use great care to avoid contact with liquid
refrigerant gas being discharged under pressure.
Sudden and irreverisble tissue damage can result from
freezing.
Wear thermal protective gloves and a face
protector or goggles in any situation where skin -
eye - contact is possible.
Prevent contact of refrigerant gas with flame or hot
surfaces.
Heat causes the refrigerant to break down
and form carbonyl chloride (phosgene), a highly toxic
and corrosive gas.
REFRIGERANT UNDER PRESSURE
is used
in
the operation of this equipment.
DEATH
or
severe injury may result if you
fail
to observe safety precautions.
Never use a heating torch on any part that contains
Do not let liquid refrigerant
Refrigerant R-22.
touch you and do not inhale refrigerant gas.