5-24.
VALVES.-Continued
(3)  Secure  valve
body
to
housing
with
hardware
and
brackets
shown  on  figure  5-12.
(4)  Reassemble  internal  components  in  the
valve  body  and
install  the  tube  and  plunger  assembly,  and  two
attaching  screws.
(5)  Install  coil  and  connector
assembly,
data
plate,
and
attaching  nut  on  valve  body.
(6)
Connect
connector
plug.
(7)
Replace
(See
(8)  Leak  test  all  newly
connected
joints
and
all
tube
connections  in  the  area.
(9)  Secure  wires  to  existing
harnesses
with
new
plastic
tie
down  straps  or  lacing  cord.
(10)  (Models  F18H-3S  and  F18H-1S)  Install  three  top  covers
(Models  F18H-3SA  and  F18H-3SB)  Install  top  cover
(11)  Evacuate  and  charge  the
refrigerant
system
in
accordance
with  paragraphs  5-15  and  5-16.
The  pressure  regulators  are  located  in  the  rear  (compressor,
The  pressure  regulators  are  factory  set
at
condenser)  compartment.
68  psig  and  sealed  so  that  they  are  not  field  adjustable.
a.
Removal.
(See
(1)
Disconnect
power
at
power
source.
(2)  (Models  F18H-3S  and  F18H-1S)  Remove  all  three  top  covers
(Models F18H-3SA and F18H-3SB) Remove top cover (para
(3)  Discharge
and
purge
refrigeration
system
per
5-11 and 5-12.
lock washer, clamp, and post spacer.
(4)
Remove
screw,
(5)  Debraze
two
tube
connections
and
remove
pressure
regulator.
Replace.
If
a
pressure
regulator
is
suspected
bad
replace
it.