TM 5-4120-386-14
The electrical system is made up of:
a.
Heater Thermostatic Switch
Heater Elements
Control Module and Components
Junction Box and Components
High/Low Pressure Cutout Switches
Wiring Harness
Compressor Wiring
Electric assemblies and groups of associated components are covered
b.
in separate paragraphs.
Disconnect air conditioner power supply before doing
maintenance work on the electrical system.
Testing and inspecting the electrical system
c.
(1)
Troubleshooting procedures for testing the electrical system to
isolate causes of trouble are discussed in Table 4-1. More detailed test
information is contained in specific paragraphs about the electrical
components.
(2)
Use a continuity tester or a multimeter set on low-resistance range
to test for continuity.
Use an insulation tester or a multimeter set on a high-resistance
(3)
range to test for short circuits between the circuit in a component and the
outside casing of the component.
When testing an electrical component, check for visible damage, and
(4)
inspect all wiring in the area for damage or loose connections.
4-20
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |