TM 5-4120-386-14
4-30. EVAPORATOR FAN AND HOUSING-Continued.
ACTION
REMARKS
LOCATION/ITEM
Assembly-
Continued
i.
Install strap (11) to inlet
rings (14 and 19) with two
screws (9) and flat washer
(10). Position strap (11)
parallel to base (40) before
final tightening of two
screws (9) and flat washer (10).
Install strap (24) to flanges
j.
(27 and 31) using two screws
(22) and flat washer (23).
k. Adjust impeller (35) inside
housing with equal space
from each inlet ring (14 and
19).
l. Tighten setscrew (38) in motor
shaft extension (39).
Industrial sealant (Item 28, App,
D) is extremely flammable. Keep
away from sparks, heat, and open
flames. Use on well ventilated
area. Avoid prolonged breathing
of vapor, prolonged skin contact
and eye contact.
m. Seal outer edge of flanges (27
and 31) to sides of housing
(37) using industrial sealant
(Item 28, App. D) and acid
swab brush (Item 29, App. D).