5-21. PRESSURE REGULATOR VALVE - Continued.
LOCATION/ITEM
ACTION
REMARKS
Removal-
Continued
Remove clamp (l), spacer (5),
c.
screw (3) and washer (2) hold-
ing valve (4).
Remove valve.
d.
Connect tubing to valve and,
Installation
a.
with dry nitrogen flowing
through tubing braze
connections.
See Para. 5-12.
Fasten clamp (1) to housing
b.
wall and valve using screw
(3), lockwasher (2) and post
spacer (5).
See
Install Solenoid coil (Ll).
c.
See
d.
Replace dehydrator.
See
Leak test refrigerant system.
e.
See
Evacuate refrigerant system.
f.
See
Charge refrigerant system.
g.
See
h.
Install Rear and Center
Top Covers.
5-73
|