5-22. ACTUATING CYLINDER-INSPECT/ADJUST/REPLACE.
This task covers:
a.
c.  Installation
Inspect
d. Adjustment
b.
Removal
INITIAL SETUP
Equipment
Condition
C o n d i t i o n Decription
Para
Top Covers removed.
Refrigerant System discharged.
Solenoid Coil (Ll) removed.
Materials/Parts
Special Tools
Tool Kit SC 5180-90-CL-N18
REMARKS
ACTION
LOCATION/ITEM
TOP OF HOUSING
Avoid bodily contact with liquid
refrigerant and avoid inhaling
refrigerant gas. Be especially
careful that refrigerant does not
come in contact with eyes. In case
of refrigerant leaks, ventilate area
immediately.
Check that power source is
disconnected. Check that system
is discharged of refrigerant.
Check for visible damage to cylinder
Inspect
and actuating wire.
Loosen mechanical post screw
a.
Removal
(1) to loosen control wire
in flexible cable (3).
Straighten control wire.
b. Disconnect flare nut (2)
from end of actuating
cylinder (4).