TM 5-4120-386-14
This task covers:
c. Repair
a.
Test
d . Installation
Removal
b.
iNITIAL SETUP
Equipment
Condition
Condition Description
Para
Top Covers removed.
Refrigerant System discharged.
Condenser Coil removed.
Special Tools
Tool Kit SC 5180-90-CL-N18
Heat Gun
Materials/Parts
Nitrogen (App.D, Item 4)
Refrigerant R-22 (App.D, Item 10)
Refrigerant R-11 (App.D, Item 12)
Brazing Alloy, Silver (App.D, Item 5 & 6)
Brazing Flux (App.D, Item 7)
Clean Glass Container
Heat Shrink Tubing
REMARKS
ACTION
LOCATION/ITEM
Disconnect air conditioner power
supply before doing maintenance
work on the electrical system.
See Wiring Dia-
Disconnect the compressor
a.
Test
grams. (Figures
electrical connector plug
E-1 and E-2)
(P10) (16).
b. Using a multimeter, test for
continuity between pins A
and B, B and C, and C and A
of the compressor electrical
receptacle (15). Continuity
should exist. If not, replace
compressor.