4120-01-238-4277">
|
|
TM 5-4120-393-14
4-36.
Control Panel Wiring Harness and Electrical Leads (cont)
INSPECTION
1.
Check connector for general condition and loose, broken, or missing contacts. Replace connector if damaged.
2.
Check individual wires for loose solder connections, terminal lug connections, cut or frayed insulation, and cut or
broken wires.
3.
See wiring diagram (para 4-13) and continuity test individual wires. Repair or replace wires with no continuity.
REPAIR
1.
See paragraph 4-34 for general wire repair instructions.
2.
See table 4-3, Wire List, for wire lengths and terminal information when individual wires are replaced.
INSTALLATION
1.
Slip beveled spacer (16) over harness (15) leads and insert harness (15) in box (6).
2.
See tags and wiring diagram, para 4-13, and reconnect harness (15) leads.
3.
Install grounding wire with grounding screw (10), lock nut (11), two lock washers (12), four flat washers (13), and nut
(14).
4.
Remove tags.
5.
Using screwdriver and wrench, secure connector J8 (9) to box (6) with four screws (7) and nuts (8).
6.
Insert rear panel (5) into box (6), align holes, and, using screwdriver and wrench, secure rear panel (5) with four
screws (3) and nuts (4).
4-85
|