4120-01-238-4277">
|
|
TM 5-4120-393-14
4-47. Junction Box Number Two Wiring Harnesses (cont)
INSPECTION
1.
Check connectors for general condition and loose, broken, or missing contacts.
2.
Replace damaged connectors.
3.
Check individual wires for loose solder connections, loose terminal lug connections, cut or frayed insulation, and cut
or broken wires.
4.
See wiring diagram, para 4-13, and continuity test individual wires.
5.
Repair or replace wires with no continuity.
REPAIR
1.
See para 4-34 for general wire repair instructions.
2.
See Wire List, table 4-3, for wire lengths and terminal/connector information.
INSTALLATION
1.
Using screwdriver and wrench install ground stud hardware (3), (4), (5), (6), and (7).
2.
See tags and wiring diagram, para 4-13 and connect leads. Remove tags.
3.
Using screwdriver and wrench, secure connectors to junction box with four screws (8), washers (9) and nuts (10).
4.
Using screwdriver, install cover (2) with eight screws (1).
NOTE
FOLLOW ON MAINTENANCE:
1. Install junction box number two. See para 4-46.
2. Connect power.
4-112
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |