4120-01-238-4277">
|
|
TM 5-4120-393-14
4-53. RFI (Radio Frequency Interference) Filters (FL1, FL2, FL3 and FL4) (cont)
INSPECTION/TESTING
1.
Check wire leads for cut or frayed insulation and cut or broken wires.
2.
Use a continuity tester or a multimeter set on the lowest OHMS scale to test each filter. If continuity is not found,
replace the affected filter.
INSTALLATION
1.
Using wrench, secure filter (5) to bracket with four washers (4) and nuts (3).
2.
Using tags and wiring diagram, para 4-13, solder leads to filters .
3.
Using screwdriver, install cover (2) with eight screws (1).
NOTE
FOLLOW ON MAINTENANCE:
1.
Install junction box number two. See para 4-46.
2.
Connect power.