TM 5-4120-393-14
4-58. Heater Elements (HR1 thru HR6) (cont)
INSPECTION/TESTING
1.
Check heater elements for damaged terminal threads and cracked or deformed outside covering.
Replace if
damaged.
2.
Using a multimeter set on lowest OHMS scale, check for continuity between the two terminal studs. Replace heater if
no continuity is indicated.
INSTALLATION
1.
Insert heater element (2) into lower mounting clip (3).
2.
Using screwdriver, secure top of heater with retainer channel (1) by tightening the two captive fasteners.
3.
See tag and wiring diagram, para 4-13, and connect wire leads.
4.
Remove tags.
5.
Carefully tie wires so they cannot contact heaters.
NOTE
FOLLOW ON MAINTENANCE:
1.
Install mist eliminator. See para 4-32.
2.
Connect power.