5-23. Pressure Relief Valve (cont)
INSTALLATION
1.
Apply antisieze tape (item 13, Appendix E) to threads of valve.
2.
Using two wrenches, screw pressure relief valve (1) in place while holding adapter fitting.
3.
Replace dehydrator. See para 5-16.
4.
Leak test all newly connected joints and those in the repair area. See para 5-12.
5.
Evacuate and charge the refrigerant system. See para 5-13 and 5-14.
NOTE
FOLLOW ON MAINTENANCE:
1. Install junction box number one. See para 4-40.
2. Install lower front panel. See para 4-24.
3. Connect power.
5-56